GS1 DataBar Truncated
GS1 DataBar Truncated is a GS1 DataBar Omnidirectional symbol that is reduced in height to as low as 13 modules. As a result, this symbology cannot be accurately read omnidirectionally.
GS1 DataBar Truncated encodes a 14-digit numeric data stream. It supports the encodation of the Global Coupon Number (GCN) and the following Global Trade Item Numbers (GTINs): GTIN-8, GTIN-12, GTIN-13, and GTIN-14. If the GCN or GTIN has fewer than 14 characters, leading zeros are appended to the left of the data so that a total of 14 characters is encoded. Due to its compact size, this symbology is mainly used in the health care industry.
GS1 DataBar Truncated is defined in ISO/IEC 24724 Information technology - Automatic identification and data capture techniques - GS1 DataBar bar code symbology specification and the GS1 General Specifications document.
Each GS1 DataBar Truncated symbol contains 46 bars and spaces in a total of 96 modules.
The symbol comprises the following elements:
-
Left guard pattern (narrow space, narrow bar)
-
Left pair of symbol characters with a finder pattern between that contains a check digit
-
Right pair of symbol characters with a finder pattern between that contains a check digit
-
Right guard pattern (narrow space, narrow bar)
The first digit is a flag that indicates whether the barcode is part of a composite barcode, and the 13 digits that follow comprise the data characters. The data itself is split into four groups called "symbol characters," which are interspersed between the two finder patterns. The left and right symbol characters are always read beginning with the character to the outside of the finder pattern. Therefore, the sequence in which symbol characters are read is: first, second, fourth, third.
The elements within each character are always read toward the finder pattern, so the second and third characters are read from right to left.
The outside characters (first and third) are 16 modules wide with four bars and four spaces. The inside characters (second and fourth) are 15 modules wide with four bars and four spaces. The finder patterns are each 15 modules wide. The first finder pattern has three spaces and two bars, and the second has two spaces and three bars.
A quiet zone is not required.
This symbology supports all numeric digits (0-9).
GS1 DataBar Truncated contains check digits in the finder patterns that use the modulo 79 (mod 79) algorithm for error correction.